一客人將一塊希捷1T硬盤送至千喜成都數(shù)據(jù)恢復(fù)中心,硬盤型號是Model : ST1000DM003-1ER162?Serial : S4Y1PA9V 電路板號為:100724095,硬盤故障表現(xiàn)為通電后硬盤尋道聲音正常,但不認(rèn)盤,解鎖板通電查看終端提示如下:
Tech Unlock Handshake: 0xAD5909E3 Reply: Spin Up SpinOK TCC:000D SNOOOZZZZZZEEE Retry EDAC Value = 000000000009435E SNOOOZZZZZZEEE Retry EDAC Value = 000000000009435E WriteFlashLogEntry PrgF LED:000000EE FAddr:0030E394 LED:000000EE FAddr:0030E394 LED:000000EE FAddr:0030E394
嘗試通電希捷硬盤短接點(diǎn)進(jìn)了F3?T級,終端提示如下:
Tech Unlock Handshake: 0xAD5909E3 Reply: Spin Up SpinO TCC:000E SNOOOZZZZZZEEE Retry EDAC Value = 000000000009435E SNOOOZZZZZZEEE Retry EDAC Value = 000000000009435E ASCII Diag mode WriteFlashLogEntry PrgF LED:000000EE FAddr:0030E394 Rst 0x40M ASCII Diag mode F3 T> Spin Up SpinOK TCC:000E SNOOOZZZZZZEEE Retry EDAC Value = 000000000009435E SNOOOZZZZZZEEE Retry EDAC Value = 000000000009435E WriteFlashLogEntry PrgF LED:000000BD FAddr:00004040 LED:000000BD FAddr:00004040 LED:000000BD FAddr:00004040
我們都知道在希捷硬盤數(shù)據(jù)恢復(fù)時遇到如果希捷硬盤不識別的情況,排除磁頭損壞后,首先進(jìn)了F3 T級備份硬盤固件,如果不能正常進(jìn)入F3 T級可以通過希捷硬盤短接點(diǎn)短接進(jìn)入F3 T級,然后再修復(fù)固件或重新編譯器都操作,但這個硬盤不論如果操作始終無法進(jìn)入F3 T級,這給硬盤數(shù)據(jù)恢復(fù)工作帶來了麻煩,千喜成都數(shù)據(jù)恢復(fù)中心工程師經(jīng)過努力成功恢復(fù)該硬盤的數(shù)據(jù),處理過程如下:
重新通電發(fā)現(xiàn)硬盤能正常識別,嘗試讀取硬盤扇區(qū)一切正常。
轉(zhuǎn)載請注明:成都千喜數(shù)據(jù)恢復(fù)中心 » 希捷ST1000DM003 1T硬盤不認(rèn)盤,終端提示LED錯誤的數(shù)據(jù)恢復(fù)